Renesas Electronics /R7FA4E10D /SCI3 /MMR

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as MMR

7 43 0 0 00 0 0 0 0 0 0 0 0 (0)RMPOL 0 (0)TMPOL 0 (0)ERTEN 0 (0)SYNVAL 0 (0)SYNSEL 0 (0)SBSEL 0 (0)MANEN

ERTEN=0, SYNSEL=0, RMPOL=0, TMPOL=0, SYNVAL=0, MANEN=0, SBSEL=0

Description

Manchester Mode Register

Fields

RMPOL

Polarity of Received Manchester Code

0 (0): Logic 0 is coded as a zero-to-one transition in Manchester code Logic 1 is coded as a one-to-zero transition in Manchester code

1 (1): Logic 0 is coded as a one-to-zero transition in Manchester code Logic 1 is coded as a zero-to-one transition in Manchester code

TMPOL

Polarity of Transmit Manchester Code

0 (0): Logic 0 is coded as a zero-to-one transition in Manchester code Logic 1 is coded as a one-to-zero transition in Manchester code

1 (1): Logic 0 is coded as a one-to-zero transition in Manchester code Logic 1 is coded as a zero-to-one transition in Manchester code

ERTEN

Manchester Edge Retiming Enable

0 (0): Disables the receive retiming function

1 (1): Enables the receive retiming function

SYNVAL

SYNC value Setting

0 (0): The start bit is added as a zero-to-one transition.

1 (1): The start bit is added as a one-to-zero transition.

SYNSEL

SYNC Select

0 (0): The start bit pattern is set with the SYNVAL bit

1 (1): The start bit pattern is set with the TSYNC bit.

SBSEL

Start Bit Select

0 (0): The start bit area consists of one bit.

1 (1): The start bit area consists of three bits (COMMAND SYNC or DATA SYNC)

MANEN

Manchester Mode Enable

0 (0): Disables the Manchester mode

1 (1): Enables the Manchester mode